Drexan MultiTraceยฎ 240V Pipe Heat Trace Plug & Play Kit โ Self-Regulating
$109.95 – $1,064.95Price range: $109.95 through $1,064.95
240V Pipe Heat Trace Plug & Play Kit Drexan MultiTraceยฎ
Product Overview
Stop relying on the cheap, โbig box storeโ heat tape that burns out after one season. Weโve taken the exact same industrial-grade Drexan MultiTraceยฎย self-regulating 240V (208V-277V) cable we install in commercial buildings and packaged it into a ready-to-use kit for your pipe trace project.
We know that terminating heat cable can be intimidating. So we did the hard work for you. Our team expertly assembles these kits in-house, ensuring every connection is watertight, electrically sound, and ready to protect your pipes the moment you plug it in.
PROFESSIONAL GRADE. PRE-TERMINATED. READY TO INSTALL.
Stop guessing with the cheap stuff. Weโve taken the exact same industrial-grade Drexan MultiTraceยฎย cable we use on our custom installs and packaged it into a ready-to-go kit for your home.
We know that terminating heat cable can be the most intimidating part of the job. So we did the heavy lifting for you. Our team expertly assembles these kits in-house, ensuring every connection is watertight, secure, and ready to battle the elements. You get the performance of a custom contractor system with the simplicity of a plug-in unit.
T1-๐ฆ WHATโS INCLUDED:
-
Drexan MultiTraceยฎ Self-Regulating Cable (Cut to your selected length)
-
Factory-Terminated Power Plug (Grounded & Lighted)
-
Pre-Sealed End Cap (Watertight termination)
WHY CHOOSE OUR PLUG โNโ PLAY KIT?
-
Self-Regulating Technology: Unlike cheap โconstant wattageโ cables that can overheat, our Steadi-On cable automatically adjusts its heat output based on the ambient temperature. It burns hot when itโs cold, and saves energy when it warms up.
-
Instant Visual Check: The integrated Lighted Plug gives you instant peace of mind. One look tells you the system is powered up and protecting your water lines. (Note: Actual plug brightness and color may vary).
-
Factory-Built Confidence: We donโt outsource our quality. These are assembled right here in Utah by pros who have been doing this for years.
T2- โ ๏ธ VOLTAGE MISMATCH: 240V CABLE ON 120V POWER WILL IT WORK? NO!
While plugging a 240V cable into a 120V outlet is electrically safe (it wonโt blow up), it effectively kills the cableโs performance.
-
The Math: Halving the voltage doesnโt just cut the heat in halfโit drops it to one-quarter.
-
The Result: A cable designed to produce 8 watts of heat will only produce 2 watts. This is not enough energy to melt snow or create a flow channel, rendering the system useless against ice dams.
-
Bottom Line: Plugging this kit into 240V wonโt burn down your house, but it willย ruin your cable and void the manufacturer warranty.
โ ๏ธ CRITICAL WARNINGS
-
GFEP PROTECTION REQUIRED: Safety is non-negotiable.
-
If you select the Standard Plug: You MUST plug this device into an outlet protected by a Ground-Fault Equipment Protector (GFEP).
-
If you select the GFEP Plug: The protection is built into the power cord.
-
-
INSULATION RECOMMENDATION: We see this all the timeโpeople tape the cable to the pipe and walk away. The pipe can still freeze. You must insulate over the cable to trap the heat against the metal/plastic.
-
DO NOT PINCH: When securing insulation or passing through walls, ensure the cable is not pinched or crushed, as this can cause a short circuit.
โ ๏ธ INSTALLATION WARNING
Must be installed by a Qualified Electrician. To maintain the UL 508A Certification and ensuring the GFEP functions correctly, all input and output wiring must adhere to local, state, and national electrical codes.
T3- ๐ TOOLS YOU WILL NEED: 3 TAPE OPTIONS
The cable creates the heat, but the installation keeps it there. Select the specific tape designed for your pipe material:
1. For PEX Piping: Reinforced Fiberglass-Foil Tape
-
The โPEX-Safeโ Solution: If you have PEX (Cross-linked Polyethylene) plumbing, you cannot use standard adhesives. PEX is chemically sensitive. Standard rubber-based adhesives found in cheap tapes can cause โChemical Migration,โleaching plasticizers out of the pipe wall. Over time, this makes the PEX brittle and prone to catastrophic cracking.
-
Chemically Inert Adhesive: This tape uses a specialized adhesive formulation designed specifically to be neutral to PEX, preventing chemical interaction and preserving the warranty of your plumbing.
-
Fiberglass Reinforcement: The foil is reinforced with a fiberglass scrim, preventing the tape from stretching or tearing as the PEX pipe expands and contracts with hot water.
-
Application: Apply continuously along the cable to ensure safe heat transfer without compromising the pipeโs molecular integrity.
2. For PVC & ABS Piping: 3Mโข Aluminum Foil Tape
-
The โThermal Bridgeโ for Rigid Plastic: PVC and ABS are durable, but they are terrible conductors of heat. If you just strap the cable to the pipe, the heat stays trapped in the jacket and doesnโt reach the water.
-
Maximized Heat Transfer: This pure aluminum tape acts as a high-efficiency radiator. By applying it over the cable, you spread the warmth across a wider surface area of the rigid plastic, forcing the heat through the pipe wall and into the water.
-
High-Temp Acrylic Adhesive: Features the industry-standard 3M acrylic adhesive that wonโt dry out or lose adhesion when the cable heats up.
-
Application: Apply continuously along the entire length of the cable.
3. For Metal Piping (Copper/Steel): 3Mโข Glass Cloth Tape
-
The High-Heat Anchor: Metal pipes conduct heat naturally, so you donโt need continuous foil coverage. However, you need a tape that wonโt degrade against the hot metal surface.
-
Industrial Strength: This woven glass-fiber tape is the industry standard for securing cable to copper and steel. It has superior tensile strength and handles the highest temperatures without stretching or popping off.
-
Application: Secure the cable to the pipe at 12-inch intervals (you do not need continuous coverage on metal).
๐ TOOLS & TIPS:
Make sure you have these items ready before you start:
-
Utility Knife / Box Cutter: Required for cutting foam or fiberglass insulation to the correct length and slitting it to fit over the pipe.
-
Scissors: Heavy-duty scissors are best for cutting the aluminum foil or glass cloth tape cleanly.
-
Clean Rags & Isopropyl Alcohol: Crucial for cleaning the pipe surface before applying the cable and tape. If the pipe is dusty or greasy, the tape will not bond, and the heat transfer will fail.
-
Tape Measure: To measure your pipe runs and insulation lengths accurately.
๐ฅ PRO-TIPS FROM THE FIELD
Advice from Eric Wimmer for a freeze-proof system.
-
The โ5 and 7โ Positions: Never run the cable on the very bottom (6 oโclock) or very top (12 oโclock) of the pipe. Sediment settles at the bottom, and air bubbles float to the topโboth block heat transfer. Stick the cable at the 5 oโclock and / or 7 oโclock position for maximum efficiency.
-
Donโt Spiral It: Professional installers run the cable straight along the pipe. It saves cable length and, when combined with aluminum tape and insulation, provides plenty of heat. Spiraling is a waste of money for most pipe trace projects.
-
Wrap the Valves: Valves and spigots are big chunks of metal that freeze first. When you get to a valve, loop a little extra slack around the valve body to ensure it stays warm, then continue down the line.
-
Tape is the Key: Donโt just tape every foot. Run a strip of aluminum tape over the entire length of the cable. This ensures 100% contact with the pipe and eliminates โair gapsโ where the cable might loseย contact with the pipe.
T4- OUR GUARANTEE:
We stand behind our craftsmanship. Every Plug โNโ Play kit is backed by an unbeatable 10-Year Limited Warranty. We build them to last, so you can sleep soundly while the temps drop.
NEED HELP WITH LAYOUT?
Check out our โDiagrams & Layoutsโ page or watch Ericโs latest tutorial to see exactly how to space your clips and apply M-1 glue for a leak-free install. ย โ Coming Soon!
Please consult the Steadi-Onย MultiTrace spec sheet for circuit capacities. Because this item is built to your unique specifications, returns are subject to a 25% restocking fee plus return shipping costs.
ADDITIONAL INFORMATION
Product Specifications:
- Ground Fault Trip Rating – 30mA
- Plug Type – 6-20P 208v-277v
- Amperage – 15 to 30 amps
- Max operating temperature – 150 degrees F
- Selections above will determine the package weight and size