PRODUCT OVERVIEW

Stop guessing and start protecting. Our custom-assembled Drexan MultiTraceยฎ Trace kits offer the industryโ€™s most reliable ice dam prevention in a format designed for easy DIY installation. This isnโ€™t a โ€œbig box storeโ€ retail cableโ€”this is the exact same industrial-grade system used by professional roofing contractors across North America.

WHICH HEAT CABLE WATTAGE DO YOU NEED?
Cable Rating 24-Hour Snowfall Threshold Recommended For Who Should Buy It?
5 Watt 2 feet (24โ€ณ) or less Standard residential roofs, gutters, and downspouts 90% of all homeowners
8 Watt Over 2 feet (24โ€ณ+) Heavy snowfall belts, lake-effect regions, shaded valleys Areas with frequent heavy accumulation
10 Watt Extreme conditions High-elevation alpine zones, sub-zero climates, commercial roofs Extreme winter climates & commercial use

The DIY Golden Rule: Over 90% of residential installations only need 5-watt cable. Unless your area regularly experiences single-day storms dumping more than 2 feet of snow, 5-watt delivers full freeze protection with optimal energy savings.

T1- OTHER MATERIALS YOU MAY NEED:
  • Aluminum Roof Clips: These corrosion-resistant clips are designed to hold the cable firmly in the โ€œzig-zagโ€ pattern on both asphalt shingles and metal roofs. Click Here

  • M-1 Structural Adhesive: This is the only glue we trust. Unlike silicone that peels off in a year, M-1 creates a permanent chemical bond (up to 400 PSI) that cures even in damp or cold conditions. Requires a caulk gun.ย Click Here
HOW MANY CLIPS & GLUE DO I NEED? FOR A STANDARD ZIG-ZAG OR VALLEY INSTALLATION, A GOOD STARTING POINT IS TO ESTIMATE 1 CLIP FOR EVERY 24 INCHES (2 FEET) OF RUN.
  • Note: This is an approximation based on typical roof layouts. Every project is unique, so donโ€™t stress about getting the number perfectโ€”you can always purchase extra clips or tubes of M-1 adhesive later if you find you need tighter spacing.

WHAT MAKES DREXAN MULTITRACEยฎ SUPERIOR?
  • Intelligent Self-Regulation: Advanced conductive core technology automatically adjusts heat output based on the outside temperature. It delivers maximum melting power when itโ€™s freezing and throttles back as things warm up to save you money on your electric bill.

  • Heavy-Duty 16 AWG Construction: Built with thicker 16 AWG nickel-plated copper bus wires. This allows for longer circuit runs and superior power distribution compared to thinner, cheaper alternatives.

  • Maximum Safety & Grounding: Features a tinned copper grounding braid for superior electrical protection and a rugged, UV-resistant polyolefin outer jacket designed to survive decades of harsh solar exposure.

  • Ready for Action: Each kit arrives pre-spliced to your specifications. Whether youโ€™re protecting a residential roof, commercial gutters, or managing pipe-trace projects, this system arrives ready for installation.

T2-โš ๏ธ VOLTAGE MISMATCH
WHY 120V MATTERS.ย  DO NOT PLUG THIS 120V KIT INTO A 240V POWER SOURCE. HERE IS WHAT HAPPENS IF YOU DO:
  • The โ€œFixed Resistanceโ€ Danger: Old-school cables have a fixed resistance. If you double the voltage (by plugging into 240V), they get hotter and hotter until they burn themselves out or start a fire.

  • The Steadi-On Difference (Fail-Safe): Our self-regulating cable is smarter. If you hit it with 240V, it tries to generate 4x the power. However, because it is self-regulating, it senses that massive heat spike and fights to regulate it downward.

  • The Result: The cable wins the safety battle, but loses the war. The internal core is pushed beyond its limit trying to keep you safe. Instead of catching fire, it will simply โ€œfail coldโ€โ€”meaning the core degrades and will permanently stop producing heat.

  • Bottom Line: Plugging this kit into 240V wonโ€™t burn down your house, but it willย ruin your cable and void the manufacturer warranty.

โš ๏ธ CRITICAL WARNING
  • It is recommended not to cut this cable. If a qualified technician cuts or modifies the cable for any reason, the warranty from Heatcable.com is immediately void. In this instance, the responsibility of the warranty falls entirely on the qualified technician performing the work. If you have excess cable, instead of cutting it, we recommend doubling it back into the gutter or downspout to increase melting power in that area.
  • Code Compliance: Installation must strictly adhere to all applicable state and local electrical codes. We recommend consulting with a licensed electrician or your local building authority to ensure full compliance.
โš ๏ธ INSTALLATION WARNING

Must be installed by a Qualified Electrician. To maintain the UL 508A Certification and ensuring the GFEP functions correctly, all input and output wiring must adhere to local, state, and national electrical codes.

โœ… COMPATIBILITY CHECKLIST

Before you buy, confirm this kit fits your home:

  • Voltage: 120V standard outlet (Verify your power outlet is 120V, not 240V).

  • Gutter Type: Safe for Aluminum, Steel, and Copper gutters/downspouts.

  • Outlet Proximity: Measure the distance from your roof edge to the outlet. You cannot use an extension cord. Ensure the kit length + lead is sufficient to reach the power source directly.

โŒ INCOMPATIBLE / DANGER

To prevent fire, shock, or system failure, AVOID the following:

  • NO EXTENSION CORDS: Never plug this kit into an extension cord. The resistance can cause overheating and fire. It must be plugged directly into a wall receptacle or controller.

  • NO BURIED CABLE: Do not install this cable inside walls, under shingles, or buried in building insulation. The cable can be installed under our Patented Thermal Cartridge System.

  • NO COILING: While Steadi-On cable is self-regulating, do not leave the cable coiled up in a tight spool while powered on. Unspool the cable completely before plugging it in to test.

โ›‘๏ธย IMPORTANT SAFETY & SPECS:
  • GFEP Protection: Safety is non-negotiable. If you do not select a kit with a built-in GFEP plug, the device must be used with a Ground-Fault Equipment Protected (GFEP) circuit.

  • System Compatibility: The GFEP can also be applied in a custom or standard controller box, provided the controller already includes a GFEP component.
  • Factory-Built Confidence: We donโ€™t outsource our quality. These are assembled right here in Utah by pros who know winter.

๐Ÿ”ฅ PRO-TIPS FROM THE FIELD: DONโ€™T COMPROMISE YOUR ROOFโ€™S INTEGRITY

To ensure a truly โ€œleak-freeโ€ installation, we strongly recommend using Patented Roof Clips and M1 Structural Adhesive.

For over 20 years, these clips have been the industry standard for securing heat cable without puncturing shingles or metal roofing. Using M1 Adhesive ensures a permanent, waterproof bond that maintains your roofโ€™s integrity while providing a professional, low-profile finish.


T-3 ๐Ÿ›  TOOLS & TIPS
  • Caulk Gun: Required for applying the M-1 Structural Adhesive. (We recommend a high-ratio โ€œdriplessโ€ gun for easier application in cold weather).

  • Extension Ladder: To safely access your roofline.

  • Clean Rags & Isopropyl Alcohol: Essential for cleaning smooth surface areasโ€”such as membrane and metal roofsโ€”where clips will be glued. Any dust or grime left on the surface will cause the adhesive to fail.

  • Light Duty Brush: Essential for brushing away loose granules and debris on asphalt shingle roofs before installing clips.
  • Measuring Tape: To ensure consistent spacing for your โ€œzig-zagโ€ pattern.

  • Pliers: Helpful for crimping the roof clips slightly if needed for a tighter hold on the cable.

T4- OUR ย GUARANTEE:

We stand behind our craftsmanship. Every Steadi-On Multitrack 240V Heat Cable is backed by an unbeatable 10-Year Limited Warranty. We build them to last, so you can sleep soundly while the snow melts.


NEED HELP WITH LAYOUT?

Check out our โ€œDiagrams & Layoutsโ€ page or watch Ericโ€™s latest tutorial to see exactly how to space your clips and apply M-1 glue for a leak-free install. ย โ€“ Coming Soon!

Please consult the Steadi-Onย MultiTrace spec sheet for circuit capacities. Because this item is built to your unique specifications, returns are subject to a 25% restocking fee plus return shipping costs.

ADDITIONAL INFORMATION

Product Specifications

  • Package Weight: 55 lbs
  • Voltage: 120v
  • Wattage: 5w, 8, 10w
  • Cable length: 500 ft
  • Type: Self-Regulating Heat Trace Cable
  • Spool Length: 500 Feet (Continuous) bulk spool
  • Application: Commercial Pipe Freeze Protection & Roof Deicing
  • Brand: Steadi-On
  • Bus Wire: 16 AWG Nickel-Plated Copper
  • Max Maintain Temp: 150ยฐF (65ยฐC)
  • Max Exposure Temp: 185ยฐF (85ยฐC) โ€“ (Won’t melt in the summer heat)
  • Jacket: UV-Stabilized Polyolefin

Related Products

klein-tools-voltage-testers-ncvt1pr-64_100
About This Product Ensure your pipe freeze protection and roof de-icing systems are powered, safe, and...
$17.98
heatcable
Milwaukee 6-in-1 Combination Pliers (48-22-3079) โ€” Heat Cable Installation & Roof De-Icing Edition Engineered...
$23.95
heatcable
Klein Tools CL120 Clamp Meter Electrical Test Kit (CL120KIT) Diagnose, balance, and commission roof de-icing...
$79.95
heatcable
Klein Tools ET600 Digital Megohmmeter / Insulation Resistance Tester Verify system integrity and ensure...
$199.95

Email Inquiry