Drexan MultiTrace 240V Self Regulating Heat Cable | 500ft Bulk
$2,210.00
Drexan Multitrace 240V Heat Cable 500ft
The Gold Standard for Large-Scale Ice Defense.
When you have a massive roof, a commercial building, or a long pipe run, you don’t buy small pre-made kits. You buy the spool that the pros use.
This is 500 feet of the exact same industrial-grade Drexan MultiTrace® cable that Eric Wimmer installs in his videos. Engineered for extreme winter conditions, this cable is the industry benchmark for reliability, energy efficiency, and long-term durability.
Why Professionals Choose Drexan MultiTrace:
-
The “16 AWG” Advantage: Most consumer-grade cables use thin 18-gauge bus wires. We use 16 AWG nickel-plated copper. Why does that matter? Thicker wire means less voltage drop, allowing you to run longer circuitson a single breaker. It’s the difference between a residential toy and a commercial tool.
-
Intelligent Self-Regulation: This cable has a brain. The conductive core automatically detects the ambient temperature at every inch of the pipe or roof. It blasts maximum heat where there is ice and snow, and throttles back where the sun is shining, saving you money on your electric bill.
- Industrial Armor: The rugged, UV-stabilized polyolefin outer jacket is built to survive decades of baking summer sun and freezing winter ice without cracking.
- Safety & Compliance: Fully UL Listed and CSA Certified for both ordinary and hazardous locations.
Future-Proof: Smart Control Ready
Don’t just melt the ice—control it. This cable is fully compatible with our integrated wireless switching solutions. Sync your system with Alexa or Google Home to manage your roof protection with voice commands.
-
“Alexa, turn on the heat cable for 48 hours.”
-
Control your system from anywhere via smartphone (requires separate controller).
Technical Specifications:
- Voltage: 240V (208V-277)
-
Spool Length: 500 Feet (Continuous)
-
Bus Wire: 16 AWG Nickel-Plated Copper
-
Watt Density: 5W, 8W, 10W per foot
- Application: Pipe Freeze Protection & Roof Deicing
-
Max Maintain Temp: 150°F (65°C)
-
Max Exposure Temp: 185°F (85°C) – (Won’t melt in the summer heat)
- Brand: Drexan
-
Jacket: UV-Stabilized Polyolefin
- Type: Self-Regulating
🛠 Tools You Will Need for Bulk Installation:
Handling a 500 ft spool requires the right setup:
-
Cable Uncoiler / Spool Stand: (Highly Recommended) Do not try to unspool this by hand on the ground. It will twist and kink. Put it on a spindle or a broom handle across two ladders to pull it off straight.
-
Megohmmeter (Megger): (Critical) You cannot install 500 feet of cable without testing the insulation resistance. A standard multimeter isn’t enough to find micro-cracks in the jacket.
-
Heavy-Duty Wire Cutters: You are cutting through thick polyolefin and 16-gauge copper.
🔥 Pro-Tips from the Field
Managing a big spool is an art form. Here is how Eric does it:
-
The “Megger” Check: Test the spool BEFORE you cut it. As soon as this arrives, use a Megohmmeter to test the entire spool while it’s still in the box. If there was shipping damage, you want to know now, not after you’ve glued 500 feet to the roof.
-
Plan Your Cuts: Don’t guess. Measure your rooflines twice. Remember to account for the “tails” needed for the power connection (usually 2-3 feet) and the end seal.
-
Label Your Circuits: When running multiple circuits from a bulk spool, label both ends of every cut immediately with a Sharpie or tape tag. Trust us, looking at 5 identical black wires in a junction box is a nightmare.
⚠️ CRITICAL WARNINGS
-
DO NOT POWER THE SPOOL: NEVER plug in or energize the heat cable while it is still coiled on the spool. The heat cannot escape, and the cable will melt into a solid plastic donut, ruining the entire 500 feet instantly.
-
CHECK CIRCUIT CAPACITIES: You cannot run all 500 feet on one breaker. You must consult the Drexan Max Circuit Length Chart to see how many feet you can put on a 15A, 20A, or 30A breaker based on your start-up temperature.
-
RETURN POLICY: This is a professional bulk product. Returns are subject to a 25% restocking fee plus return shipping costs. Please verify your measurements before ordering.
OUR GUARANTEE:
We stand behind our craftsmanship. Every Plug ‘N’ Play kit is backed by an unbeatable 10-Year Limited Warranty. We build them to last, so you can sleep soundly while the temps drop.
NEED HELP WITH LAYOUT?
Check out our “Diagrams & Layouts” page or watch Eric’s latest tutorial to see exactly how to space your clips and apply M-1 glue for a leak-free install. – Coming Soon!
Installation Support:
We recommend pairing this cable with our 20-year proven, no-penetration roof clips and M-1 Structural Adhesive for a completely leak-free system.
WHAT’S INCLUDED
- Drexan MultiTrace® Self-Regulating Cable (The gold standard for longevity)
- Factory-Terminated Power Plug (Grounded & Lighted) OR
- GFEP Factory-Terminated Power Plug (Grounded & Not lighted)
OTHER MATERIALS NEEDED:
- Aluminum Roof Clips: These corrosion-resistant clips are designed to hold the cable firmly in the “zig-zag” pattern on both asphalt shingles and metal roofs. Click Here
- M-1 Structural Adhesive: This is the only glue we trust. Unlike silicone that peels off in a year, M-1 creates a permanent chemical bond (up to 400 PSI) that cures even in damp or cold conditions. Requires a caulk gun. Click Here
How many Clips & Glue do I need? For a standard zig-zag or valley installation, a good starting point is to estimate 1 clip for every 24 inches (2 feet) of run.
- Note: This is an approximation based on typical roof layouts. Every project is unique, so don’t stress about getting the number perfect—you can always purchase extra clips or tubes of M-1 adhesive later if you find you need tighter spacing.
WHY CHOOSE A Heatcable.com ‘N’ PLAY KIT?
- Skip the Electrician: No hard-wiring required. These kits come with a pre-terminated, grounded power plug. Just mount the cable and plug it in.
- Instant Visual Check: The integrated Lighted Plug gives you instant peace of mind. One look tells you the system is powered up and melting snow. (Note: Actual plug brightness and color may vary).
VOLTAGE MISMATCH
WHY 120V MATTERS. DO NOT PLUG THIS 120V KIT INTO A 240V POWER SOURCE. HERE IS WHAT HAPPENS IF YOU DO:
The “Fixed Resistance” Danger: Old-school cables have a fixed resistance. If you double the voltage (by plugging into 240V), they get hotter and hotter until they burn themselves out or start a fire.
The Drexan Difference (Fail-Safe): Our self-regulating cable is smarter. If you hit it with 240V, it tries to generate 4x the power. However, because it is self-regulating, it senses that massive heat spike and fights to regulate it downward.
The Result: The cable wins the safety battle, but loses the war. The internal core is pushed beyond its limit trying to keep you safe. Instead of catching fire, it will simply “fail cold”—meaning the core degrades and will permanently stop producing heat.
Bottom Line: Plugging this kit into 240V won’t burn down your house, but it will ruin your cable and void the manufacturer warranty.
⚠️ CRITICAL WARNING
- It is recommended not to cut this cable. If a qualified technician cuts or modifies the cable for any reason, the warranty from Heatcable.com is immediately void. In this instance, the responsibility of the warranty falls entirely on the qualified technician performing the work. If you have excess cable, instead of cutting it, we recommend doubling it back into the gutter or downspout to increase melting power in that area.
- Code Compliance: Installation must strictly adhere to all applicable state and local electrical codes. We recommend consulting with a licensed electrician or your local building authority to ensure full compliance.
⚠️ INSTALLATION WARNING
Must be installed by a Qualified Electrician. To maintain the UL 508A Certification and ensuring the GFEP functions correctly, all input and output wiring must adhere to local, state, and national electrical codes.
✅ COMPATIBILITY CHECKLIST
Before you buy, confirm this kit fits your home:
- Voltage: 120V standard outlet (Verify your power outlet is 120V, not 240V).
- Gutter Type: Safe for Aluminum, Steel, and Copper gutters/downspouts.
- Outlet Proximity: Measure the distance from your roof edge to the outlet. You cannot use an extension cord. Ensure the kit length + lead is sufficient to reach the power source directly.
❌ INCOMPATIBLE / DANGER
To prevent fire, shock, or system failure, AVOID the following:
- NO EXTENSION CORDS: Never plug this kit into an extension cord. The resistance can cause overheating and fire. It must be plugged directly into a wall receptacle or controller.
- NO BURIED CABLE: Do not install this cable inside walls, under shingles, or buried in building insulation. The cable can be installed under our Patented Thermal Cartridge System.
- NO COILING: While Drexan cable is self-regulating, do not leave the cable coiled up in a tight spool while powered on. Unspool the cable completely before plugging it in to test.
⛑️ Important Safety & Specs:
- GFEP Protection: Safety is non-negotiable. If you do not select a kit with a built-in GFEP plug, the device must be used with a Ground-Fault Equipment Protected (GFEP) circuit.
- System Compatibility: The GFEP can also be applied in a custom or standard controller box, provided the controller already includes a GFEP component.
- Factory-Built Confidence: We don’t outsource our quality. These are assembled right here in Utah by pros who know winter.
TOOLS & TIPS
- Caulk Gun: Required for applying the M-1 Structural Adhesive. (We recommend a high-ratio “dripless” gun for easier application in cold weather).
- Extension Ladder: To safely access your roofline.
- Clean Rags & Isopropyl Alcohol: Essential for cleaning smooth surface areas—such as membrane and metal roofs—where clips will be glued. Any dust or grime left on the surface will cause the adhesive to fail.
- Light Duty Brush: Essential for brushing away loose granules and debris on asphalt shingle roofs before installing clips.
- Measuring Tape: To ensure consistent spacing for your “zig-zag” pattern.
- Pliers: Helpful for crimping the roof clips slightly if needed for a tighter hold on the cable.
🔥 PRO-TIPS FROM THE FIELD
- Don’t just install it—install it like a pro.
- The “Hershey Kiss” Method: When using the M-1 glue, don’t smear it flat like paint. Apply a nickel-sized dollop (shaped like a Hershey Kiss) under the clip. Press the clip down until glue pushes through the holes, but leave a layer of adhesive between the clip and the roof. This creates a chemical bond that lasts for decades.
- Create the “Melt Channel”: Remember, the cable doesn’t melt the whole roof; it creates a path for water to escape. Ensure your cable extends past the roof edge (1 inches or more) over the gutter to prevent an ice dam from forming right at the lip.
- Check Your GFEP: If you aren’t buying the GFEP plug option, you must plug this into an outlet protected by a GFEP breaker. We recommend testing the breaker before every winter season. Note: Your GFEP may also be in your controller.
- The “Drip Loop”: When plugging the unit in, make sure there is a small loop in the power cord below the outlet. This prevents water from running down the cord and directly into your electrical socket.
Our Guarantee
We stand behind our craftsmanship. Every Plug ‘N’ Play kit is backed by an unbeatable 10-Year Limited Warranty. We build them to last, so you can sleep soundly while the snow melts.
NEED HELP WITH LAYOUT?
Check out our “Diagrams & Layouts” page or watch Eric’s latest tutorial to see exactly how to space your clips and apply M-1 glue for a leak-free install. – Coming Soon!
Please consult the Drexan MultiTrace spec sheet for circuit capacities. Because this item is built to your unique specifications, returns are subject to a 25% restocking fee plus return shipping costs.
ADDITIONAL INFORMATION
Product Specifications
Package dimensions:
- Package Weight: 55 lbs
- Voltage: 208-277v
- Wattage: 5w, 8, 10w
- Cable length: 500 ft




